User Manual
i Series / iX Series 3
2.1.2 Output
(ALL SPECIFICATIONS ARE FOR AC AND DC UNLESS NOTED OTHERWISE)
Low: 0 - 135 VAC / High: 0 - 270 VAC
0 - 150 VAC / High: 0 - 300 VAC
Low: 0 - 135 VDC / High: 0 - 270 VDC
0 - 150 VDC / High: 0 - 300 VDC
AC+DC Mode
iX Models only.
AC: Low: 0 - 150 V / High: 0 - 300 V
DC Offset: Low 0 - 150 V / High; 0 - 250 V
AC: 01. V
DC Offset: 0.01 V < 0.5 V
0.1 V 0.6 - 25 V
1 V > 25 V
0.5% of range, 16 to 400 Hz.
0.5% of range, 16 to 400 Hz.
5% of range ± 0.1 VDC.< 25VDC
5% of range ± 1 VDC.> 25VDC
Voltage Distortion
1
:
(linear load)
1% max THD at 50/60 Hz
2% max THD at 400 Hz
1% max THD at 50/60 Hz
2% max THD at 400 Hz
0.5% DC to 100 Hz
2.2% to 500 Hz (135 range)
0.6% to 500 Hz (270 range)
0.5% DC to 100 Hz.
2.2% to 500 Hz (135/150 range)
0.6% to 500 Hz (270/300 range)
0.1% for 10% input line
change
0.1% for 10% input line change
Power: (per phase, either range, at full scale voltage)
3001, 9003i/iX
5001, 15003i/iX
10001i/iX
3000 VA AC, 2100 W DC
5000 VA AC, 3500 W DC
10000 VA AC, 7000 W DC
3000 VA AC, 2100 W DC
5000 VA AC, 3500 W DC
10000 VA AC, 7000 W DC
1
The distortion specification for the 3001i and iX is valid for an input voltage range of 197-264 V.